Annual operating energy savings of liquid desiccant and evaporative-cooling-assisted 100% outdoor air system MH Kim, JY Park, MK Sung, AS Choi, JW Jeong Energy and Buildings 76, 538-550, 2014 | 98 | 2014 |
The characteristics of photosensors and electronic dimming ballasts in daylight responsive dimming systems AS Choi, KD Song, YS Kim Building and environment 40 (1), 39-50, 2005 | 91 | 2005 |
A study on the subjective response for corrected colour temperature conditions in a specific space BC Park, JH Chang, YS Kim, JW Jeong, AS Choi Indoor and Built Environment 19 (6), 623-637, 2010 | 71 | 2010 |
Application of the space syntax theory to quantitative street lighting design AS Choi, YO Kim, ES Oh, YS Kim Building and environment 41 (3), 355-366, 2006 | 58 | 2006 |
Evaluation of optimized PV power generation and electrical lighting energy savings from the PV blind-integrated daylight responsive dimming system using LED lighting SH Kim, IT Kim, AS Choi, MK Sung Solar energy 107, 746-757, 2014 | 55 | 2014 |
Effects of correlated color temperature on focused and sustained attention under white LED desk lighting RH Huang, L Lee, YA Chiu, Y Sun Color Research & Application 40 (3), 281-286, 2015 | 48 | 2015 |
Performance of integrated systems of automated roller shade systems and daylight responsive dimming systems BC Park, AS Choi, JW Jeong, ES Lee Building and Environment 46 (3), 747-757, 2011 | 47 | 2011 |
On the prediction of energy savings for a daylight dimming system A Choi, RG Mistrick Journal of the Illuminating Engineering Society 26 (2), 77-90, 1997 | 43 | 1997 |
Analysis of daylight responsive dimming system performance RG Mistrick Building and Environment 34 (3), 231-243, 1998 | 42 | 1998 |
Energy conservation potential of an indirect and direct evaporative cooling assisted 100% outdoor air system MH Kim, JH Kim, OH Kwon, AS Choi, JW Jeong Building Services Engineering Research and Technology 32 (4), 345-360, 2011 | 41 | 2011 |
Design of a connected security lighting system for pedestrian safety in smart cities Y Cho, H Jeong, A Choi, M Sung Sustainability 11 (5), 1308, 2019 | 40 | 2019 |
Development of a Colour Quality Assessment Tool for indoor luminous environments affecting the circadian rhythm of occupants IT Kim, AS Choi, MK Sung Building and Environment 126, 252-265, 2017 | 40 | 2017 |
Precise control of a correlated color temperature tunable luminaire for a suitable luminous environment IT Kim, AS Choi, JW Jeong Building and Environment 57, 302-312, 2012 | 37 | 2012 |
Toward the accuracy of prediction for energy savings potential and system performance using the daylight responsive dimming system H Choi, S Hong, A Choi, M Sung Energy and Buildings 133, 271-280, 2016 | 36 | 2016 |
Platform design for lifelog-based smart lighting control Y Cho, J Seo, H Lee, S Choi, A Choi, M Sung, Y Hur Building and Environment 185, 107267, 2020 | 32 | 2020 |
Experimental study on the heat exchange effectiveness of a dry coil indirect evaporation cooler under various operating conditions MH Kim, JH Kim, AS Choi, JW Jeong Energy 36 (11), 6479-6489, 2011 | 31 | 2011 |
Improvement in demand-controlled ventilation simulation on multi-purposed facilities under an occupant based ventilation standard JW Jeong, A Choi, ST No Simulation Modelling Practice and Theory 18 (1), 51-62, 2010 | 29 | 2010 |
An experimental study of the optimum spatial characteristics and location of photosensor for daylight responsive dimming systems BK Jung, AS Choi J. Korean Inst. Illum. Electr. Install. Eng 17, 8-14, 2003 | 29 | 2003 |
Development of a daylight responsive dimming system and preliminary evaluation of system performance AS Choi, MK Sung Building and environment 35 (7), 663-676, 2000 | 28 | 2000 |
A study of luminous environment for standard illuminance in residential areas JE Lee, AS Choi Journal of the Korean Institute of Illuminating and Electrical Installation …, 2005 | 26 | 2005 |