Geun Young Yun
Geun Young Yun
Associate Professor of Architectural Engineering, Kyung Hee University
khu.ac.kr의 이메일 확인됨 - 홈페이지
제목인용연도
Time-dependent occupant behaviour models of window control in summer
GY Yun, K Steemers
Building and environment 43 (9), 1471-1482, 2008
2462008
Household energy consumption: a study of the role of occupants
K Steemers, GY Yun
Building Research & Information 37 (5-6), 625-637, 2009
2382009
Behavioural, physical and socio-economic factors in household cooling energy consumption
GY Yun, K Steemers
Applied Energy 88 (6), 2191-2200, 2011
1822011
Thermal performance of a naturally ventilated building using a combined algorithm of probabilistic occupant behaviour and deterministic heat and mass balance models
GY Yun, P Tuohy, K Steemers
Energy and buildings 41 (5), 489-499, 2009
1492009
Thermal performance of a naturally ventilated building using a combined algorithm of probabilistic occupant behaviour and deterministic heat and mass balance models
GY Yun, P Tuohy, K Steemers
Energy and buildings 41 (5), 489-499, 2009
1492009
Effects of occupancy and lighting use patterns on lighting energy consumption
GY Yun, H Kim, JT Kim
Energy and Buildings 46, 152-158, 2012
1412012
Design and overall energy performance of a ventilated photovoltaic façade
GY Yun, M McEvoy, K Steemers
Solar Energy 81 (3), 383-394, 2007
1342007
A field survey of visual comfort and lighting energy consumption in open plan offices
GY Yun, HJ Kong, H Kim, JT Kim
Energy and Buildings 46, 146-151, 2012
762012
Development of the adaptive PMV model for improving prediction performances
JT Kim, JH Lim, SH Cho, GY Yun
Energy and Buildings 98, 100-105, 2015
592015
Natural ventilation in practice: linking facade design, thermal performance, occupant perception and control
GY Yun, K Steemers, N Baker
Building Research & Information 36 (6), 608-624, 2008
532008
View types and luminance effects on discomfort glare assessment from windows
JY Shin, GY Yun, JT Kim
Energy and Buildings 46, 139-145, 2012
522012
Night-time naturally ventilated offices: Statistical simulations of window-use patterns from field monitoring
GY Yun, K Steemers
Solar Energy 84 (7), 1216-1231, 2010
452010
Influence of window views on the subjective evaluation of discomfort glare
GY Yun, JY Shin, JT Kim
Indoor and Built Environment 20 (1), 65-74, 2011
432011
Implications of urban settings for the design of photovoltaic and conventional façades
GY Yun, K Steemers
Solar Energy 83 (1), 69-80, 2009
392009
Evaluation of daylighting effectiveness and energy saving potentials of light-pipe systems in buildings
JY Shin, GY Yun, JT Kim
Indoor and Built Environment 21 (1), 129-136, 2012
332012
The effect of seasons and prevailing environments on adaptive comfort temperatures in open plan offices
GY Yun, HJ Kong, JT Kim
Indoor and built environment 21 (1), 41-47, 2012
312012
A field survey of occupancy and air-conditioner use patterns in open plan offices
GY Yun, HJ Kong, JT Kim
Indoor and Built environment 20 (1), 137-147, 2011
262011
Performance prediction by modelling of a light-pipe system used under the climate conditions of Korea
GY Yun, T Hwang, JT Kim
Indoor and Built Environment 19 (1), 137-144, 2010
262010
Influences of perceived control on thermal comfort and energy use in buildings
GY Yun
Energy and Buildings 158, 822-830, 2018
222018
Energy performance of direct expansion air handling unit in office buildings
GY Yun, J Choi, JT Kim
Energy and Buildings 77, 425-431, 2014
222014
현재 시스템이 작동되지 않습니다. 나중에 다시 시도해 주세요.
학술자료 1–20