Follow
Valentina Hartwig
Valentina Hartwig
Institute of Clinical Physiology, CNR, Pisa, Italy
Verified email at ifc.cnr.it
Title
Cited by
Cited by
Year
Biological effects and safety in magnetic resonance imaging: a review
V Hartwig, G Giovannetti, N Vanello, M Lombardi, L Landini, S Simi
International journal of environmental research and public health 6 (6 …, 2009
3122009
Is the genotoxic effect of magnetic resonance negligible? Low persistence of micronucleus frequency in lymphocytes of individuals after cardiac scan
S Simi, M Ballardin, M Casella, D De Marchi, V Hartwig, G Giovannetti, ...
Mutation Research/Fundamental and Molecular Mechanisms of Mutagenesis 645 (1 …, 2008
932008
Sensing glove for brain studies: design and assessment of its compatibility for fMRI with a robust test
N Vanello, V Hartwig, M Tesconi, E Ricciardi, A Tognetti, G Zupone, ...
IEEE/Asme Transactions on Mechatronics 13 (3), 345-354, 2008
412008
Low-field MR coils: comparison between strip and wire conductors
G Giovannetti, V Hartwig, L Landini, MF Santarelli
Applied Magnetic Resonance 39, 391-399, 2010
372010
Hyperpolarized MRS surface coil: Design and signal‐to‐noise ratio estimation
G Giovannetti, F Frijia, L Menichetti, M Milanesi, JH Ardenkjaer‐Larsen, ...
Medical physics 37 (10), 5361-5369, 2010
352010
Multimodal imaging for the detection of brown adipose tissue activation in women: a pilot study using NIRS and infrared thermography
V Hartwig, L Guiducci, M Marinelli, L Pistoia, TM Tegrimi, G Iervasi, ...
Journal of Healthcare Engineering 2017, 2017
282017
Numerical analysis of electromagnetic field exposure from 5G mobile communications at 28 GHZ in adults and children users for real-world exposure scenarios
MS Morelli, S Gallucci, B Siervo, V Hartwig
International Journal of Environmental Research and Public Health 18 (3), 1073, 2021
272021
A novel tool for estimation of magnetic resonance occupational exposure to spatially varying magnetic fields
V Hartwig, N Vanello, G Giovannetti, M Lombardi, L Landini, MF Santarelli
Magnetic Resonance Materials in Physics, Biology and Medicine 24, 323-330, 2011
262011
Hyperpolarized 13C MRS Cardiac Metabolism Studies in Pigs: Comparison Between Surface and Volume Radiofrequency Coils
G Giovannetti, V Hartwig, F Frijia, L Menichetti, V Positano, ...
Applied Magnetic Resonance 42, 413-428, 2012
252012
Low field elliptical MR coil array designed by FDTD
G Giovannetti, V Hartwig, V Viti, P Zadaricchio, L Meini, L Landini, ...
Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering: An …, 2008
252008
Engineering for safety assurance in MRI: analytical, numerical and experimental dosimetry
V Hartwig
Magnetic resonance imaging 33 (5), 681-689, 2015
242015
Radiofrequency coils for magnetic resonance applications: Theory, design, and evaluation
G Giovannetti, V Hartwig, V Positano, N Vanello
Critical Reviews™ in Biomedical Engineering 42 (2), 2014
242014
Classical and lateral skin effect contributions estimation in strip MR coils
G Giovannetti, V Hartwig, L Landini, MF Santarelli
Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering 41 (2 …, 2012
242012
B1+/actual flip angle and reception sensitivity mapping methods: Simulation and comparison
V Hartwig, N Vanello, G Giovannetti, D De Marchi, M Lombardi, L Landini, ...
Magnetic resonance imaging 29 (5), 717-722, 2011
242011
Numerical calculation of peak-to-average specific absorption rate on different human thorax models for magnetic resonance safety considerations
V Hartwig, G Giovannetti, N Vanello, L Landini, MF Santarelli
Applied Magnetic Resonance 38, 337-348, 2010
232010
Application of undersampling technique for the design of an NMR signals digital receiver
G Giovannetti, V Hartwig, V Viti, G Gaeta, R Francesconi, L Landini, ...
Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering: An …, 2006
232006
A pilot study of infrared thermography based assessment of local skin temperature response in overweight and lean women during oral glucose tolerance test
B Jalil, V Hartwig, D Moroni, O Salvetti, A Benassi, Z Jalil, L Pistoia, ...
Journal of Clinical Medicine 8 (2), 260, 2019
212019
Occupational exposure to electromagnetic fields in magnetic resonance environment: basic aspects and review of exposure assessment approaches
V Hartwig, S Romeo, O Zeni
Medical & biological engineering & computing 56, 531-545, 2018
212018
Effectiveness of Blue light photobiomodulation therapy in the treatment of chronic wounds. Results of the Blue Light for Ulcer Reduction (BLUR) Study.
M Fraccalvieri, G Amadeo, P Bortolotti, M Ciliberti, A Garrubba, G Mosti, ...
Italian Journal of Dermatology and Venereology 157 (2), 187-194, 2021
192021
Active mechatronic interface for haptic perception studies with functional magnetic resonance imaging: compatibility and design criteria
R Gassert, N Vanello, D Chapuis, V Hartwig, E Scilingo, A Bicchi, ...
Proceedings 2006 IEEE International Conference on Robotics and Automation …, 2006
192006
The system can't perform the operation now. Try again later.
Articles 1–20