Follow
Ramar RAMARAJ
Title
Cited by
Cited by
Year
Intercomparison of gamma scattering, gammatography, and radiography techniques for mild steel nonuniform corrosion detection
P Priyada, M Margret, R Ramar, Shivaramu, M Menaka, L Thilagam, ...
Review of Scientific Instruments 82 (3), 035115, 2011
412011
Intercomparison of gamma ray scattering and transmission techniques for fluid–fluid and fluid–air interface levels detection and density measurements
P Priyada, M Margret, R Ramar, Shivaramu
Applied Radiation and Isotopes 70 (3), 462-469, 2012
362012
Determining the water content in concrete by gamma scattering method
P Priyada, R Ramar, Shivaramu
Annals of Nuclear Energy 63, 565-570, 2014
252014
Application of gamma ray scattering technique for non-destructive evaluation of voids in concrete
P Priyada, R Ramar, Shivaramu
Applied Radiation and Isotopes 74, 13-22, 2013
162013
An improved Compton scattering method for determination of concentration of solutions
P Priyada, R Ramar, Shivaramu
Applied Radiation and Isotopes 70 (10), 2421-2427, 2012
112012
On the evaluation of correction terms in Gauss–Legendre quadrature
N Mohankumar, S Sen, R Ramar
Computer Physics Communications 181 (1), 17-20, 2010
72010
Gamma photon techniques for detection of nucleation in superheated emulsion detectors for neutron dosimetry
P Priyada, R Ramar, H Krishnan, S Viswanathan, Shivaramu.
Radiation protection dosimetry 158 (1), 100-106, 2014
32014
Monte Carlo simulation of an HPGe detector for detection of 239Pu in waste assay system
SP Narayanam, M Manohari, R Ramar, V Subramanian, R Mathiyarasu, ...
Applied Radiation and Isotopes 152, 127-134, 2019
22019
Monte Carlo-based investigation of Waste Assay Computed Tomography (WACT)
PN Sujatha, M Manohari, R Ramar, V Subramanian, R Mathiyarusu, ...
Proceedings of the thirty-third IARP international conference on …, 2018
12018
Non-destructive Waste Assay Computed Tomography (NDWACT) System
R Ramar
IGC Newsletter 110, 4-6, 2016
12016
Investigation of CT Linearity and Establishing the Density Calibration Curve for the Gamma Ray CT System
R Ramar, M Menaka, V Subramanian, R Venkatesan, S Athmalingam, ...
Conference and Exhibition on Non Destructive Evaluation, 301-313, 2020
2020
Feasibility studies on neutron noise analysis with MCA/MCS and list-mode
A Rawat, R Ramar, R Mathiyarasu, S Chandrasekaran, ...
Proceedings of the thirty-third IARP international conference on …, 2018
2018
Identification of Pu and determination of activity in a simulated waste drum for WACT System
R Ramar, V Subramanian, R Baskaran, B Venkatraman
Proceedings of the thirty-third IARP international conference on …, 2018
2018
Estimation of gamma dose rate and shielding requirement for Waste Inspection Tomography (WIT) assay room
R Ramar, S Chandrasekaran, R Baskaran, B Venkatraman
Proceedings of the international conference on radiological safety in …, 2016
2016
Indigenously developed fully automated tomography gamma scanner for assay of drummed nuclear material
R Ramar, R Baskaran, B Venkatraman, GV Kishore, MB Rajhans, ...
Proceedings of the twenty-fifth national seminar and international …, 2015
2015
Waste Inspection Tomography for Non-Destructive Evaluation (WITNDA)
R Ramar, P Priyada, Shivaramu, B Venkatraman
Proceedings of the nineteenth national symposium on radiation physics …, 2012
2012
5th Pan American Conference for NDT
Shivaramu, P Priyada, M Margret, R Ramar
The system can't perform the operation now. Try again later.
Articles 1–17