Æȷοì
Jin Keun Seo
Á¦¸ñ
Àοë
Àοë
¿¬µµ
Deep learning for undersampled MRI reconstruction
CM Hyun, HP Kim, SM Lee, S Lee, JK Seo
Physics in Medicine & Biology 63 (13), 135007, 2018
5132018
Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm
O Kwon, EJ Woo, JR Yoon, JK Seo
IEEE Transactions on Biomedical Engineering 49 (2), 160-167, 2002
3662002
Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging
EJ Woo, JK Seo
Physiological measurement 29 (10), R1, 2008
2722008
Reconstruction of conductivity and current density images using only one component of magnetic field measurements
JK Seo, JR Yoon, EJ Woo, O Kwon
IEEE Transactions on Biomedical Engineering 50 (9), 1121-1124, 2003
2552003
Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography
SH Oh, BI Lee, EJ Woo, SY Lee, MH Cho, O Kwon, JK Seo
Physics in Medicine & Biology 48 (19), 3101, 2003
2472003
Magnetic resonance electrical impedance tomography (MREIT)
JK Seo, EJ Woo
SIAM review 53 (1), 40-68, 2011
2022011
J-substitution algorithm in magnetic resonance electrical impedance tomography (MREIT): phantom experiments for static resistivity images
HS Khang, BI Lee, SH Oh, EJ Woo, SY Lee, MH Cho, O Kwon, JR Yoon, ...
IEEE transactions on medical imaging 21 (6), 695-702, 2002
1592002
Nonlinear inverse problems in imaging
JK Seo, EJ Woo
John Wiley & Sons, 2012
1582012
The layer potential technique for the inverse conductivity problem
H Kang, JK Seo
Inverse Problems 12 (3), 267, 1996
1571996
A real time algorithm for the location search of discontinuous conductivities with one measurement
O Kwon, JK Seo, JR Yoon
Communications on Pure and Applied Mathematics: A Journal Issued by the ¡¦, 2002
1402002
Level set-based bimodal segmentation with stationary global minimum
SH Lee, JK Seo
IEEE transactions on image processing 15 (9), 2843-2852, 2006
1392006
Recent progress and future challenges in MR electric properties tomography
U Katscher, DH Kim, JK Seo
Computational and mathematical methods in medicine 2013, 2013
1332013
CT sinogram‐consistency learning for metal‐induced beam hardening correction
HS Park, SM Lee, HP Kim, JK Seo, YE Chung
Medical physics 45 (12), 5376-5384, 2018
128*2018
The inverse conductivity problem with one measurement: stability and estimation of size
H Kang, JK Seo, D Sheen
SIAM Journal on Mathematical Analysis 28 (6), 1389-1405, 1997
1281997
Frequency-difference electrical impedance tomography (fdEIT): algorithm development and feasibility study
JK Seo, J Lee, SW Kim, H Zribi, EJ Woo
Physiological measurement 29 (8), 929, 2008
1262008
Noise removal with Gauss curvature-driven diffusion
SH Lee, JK Seo
IEEE Transactions on Image Processing 14 (7), 904-909, 2005
1262005
In Vivo High-ResolutionConductivity Imaging of the Human Leg Using MREIT: The First Human Experiment
HJ Kim, YT Kim, AS Minhas, WC Jeong, EJ Woo, JK Seo, OJ Kwon
IEEE transactions on medical imaging 28 (11), 1681-1687, 2009
1182009
Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1: impedance spectroscopy and time-difference imaging
TI Oh, H Koo, KH Lee, SM Kim, J Lee, SW Kim, JK Seo, EJ Woo
Physiological measurement 29 (3), 295, 2008
1142008
Noise analysis in magnetic resonance electrical impedance tomography at 3 and 11 T field strengths
R Sadleir, S Grant, SU Zhang, BI Lee, HC Pyo, SH Oh, C Park, EJ Woo, ...
Physiological measurement 26 (5), 875, 2005
1142005
Electrical conductivity images of biological tissue phantoms in MREIT
SH Oh, BI Lee, EJ Woo, SY Lee, TS Kim, O Kwon, JK Seo
Physiological Measurement 26 (2), S279, 2005
1142005
ÇöÀç ½Ã½ºÅÛÀÌ ÀÛµ¿µÇÁö ¾Ê½À´Ï´Ù. ³ªÁß¿¡ ´Ù½Ã ½ÃµµÇØ ÁÖ¼¼¿ä.
ÇмúÀÚ·á 1–20