A digital preclinical PET/MRI insert and initial results B Weissler, P Gebhardt, PM Dueppenbecker, J Wehner, D Schug, ... IEEE transactions on medical imaging 34 (11), 2258-2270, 2015 | 122 | 2015 |
Initial PET performance evaluation of a preclinical insert for PET/MRI with digital SiPM technology D Schug, C Lerche, B Weissler, P Gebhardt, B Goldschmidt, J Wehner, ... Physics in Medicine & Biology 61 (7), 2851, 2016 | 80 | 2016 |
High intensity neutrino oscillation facilities in Europe TR Edgecock, O Caretta, T Davenne, C Densam, M Fitton, D Kelliher, ... Physical Review Special Topics-Accelerators and Beams 16 (2), 021002, 2013 | 79 | 2013 |
MR compatibility aspects of a silicon photomultiplier-based PET/RF insert with integrated digitisation B Weissler, P Gebhardt, CW Lerche, J Wehner, T Solf, B Goldschmidt, ... Physics in Medicine & Biology 59 (17), 5119, 2014 | 72 | 2014 |
PET/MRI insert using digital SiPMs: investigation of MR-compatibility J Wehner, B Weissler, P Dueppenbecker, P Gebhardt, D Schug, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2014 | 72 | 2014 |
MR-compatibility assessment of the first preclinical PET-MRI insert equipped with digital silicon photomultipliers J Wehner, B Weissler, PM Dueppenbecker, P Gebhardt, B Goldschmidt, ... Physics in Medicine & Biology 60 (6), 2231, 2015 | 71 | 2015 |
USPIO-labeled textile materials for non-invasive MR imaging of tissue-engineered vascular grafts ME Mertens, S Koch, P Schuster, J Wehner, Z Wu, F Gremse, V Schulz, ... Biomaterials 39, 155-163, 2015 | 68 | 2015 |
Data processing for a high resolution preclinical PET detector based on Philips DPC digital SiPMs D Schug, J Wehner, B Goldschmidt, C Lerche, PM Dueppenbecker, ... IEEE Transactions on Nuclear Science 62 (3), 669-678, 2015 | 47 | 2015 |
Design concept of world's first preclinical PET/MR insert with fully digital silicon photomultiplier technology B Weissler, P Gebhardt, P Düppenbecker, B Goldschmidt, A Salomon, ... 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record …, 2012 | 43 | 2012 |
ToF performance evaluation of a PET insert with Digital Silicon Photomultiplier technology during MR operation D Schug, J Wehner, PM Dueppenbecker, B Weissler, P Gebhardt, ... EJNMMI physics 1, 1-2, 2014 | 37* | 2014 |
PET performance and MRI compatibility evaluation of a digital, ToF-capable PET/MRI insert equipped with clinical scintillators D Schug, J Wehner, PM Dueppenbecker, B Weissler, P Gebhardt, ... Physics in Medicine & Biology 60 (18), 7045, 2015 | 33 | 2015 |
Software-based real-time acquisition and processing of PET detector raw data B Goldschmidt, D Schug, CW Lerche, A Salomon, P Gebhardt, B Weissler, ... IEEE Transactions on Biomedical Engineering 63 (2), 316-327, 2015 | 30 | 2015 |
Development of an MRI compatible digital SiPM based PET detector stack for simultaneous preclinical PET/MRI PM Düppenbecker, B Weissler, P Gebhardt, D Schug, J Wehner, ... 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record …, 2012 | 29 | 2012 |
Gradient transparent RF housing for simultaneous PET/MRI using carbon fiber composites PM Düppenbecker, J Wehner, W Renz, S Lodomez, D Truhn, PK Marsden, ... 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record …, 2012 | 29 | 2012 |
Development of an MRI-compatible digital SiPM detector stack for simultaneous PET/MRI PM Düppenbecker, B Weissler, P Gebhardt, D Schug, J Wehner, ... Biomedical Physics & Engineering Express 2 (1), 015010, 2016 | 28 | 2016 |
FPGA-based RF interference reduction techniques for simultaneous PET–MRI P Gebhardt, J Wehner, B Weissler, R Botnar, PK Marsden, V Schulz Physics in Medicine & Biology 61 (9), 3500, 2016 | 21 | 2016 |
Design of a neutrino source based on beta beams E Wildner, C Hansen, E Benedetto, E Jensen, T Stora, TM Mendonca, ... Physical Review Special Topics-Accelerators And Beams 17 (7), 071002, 2014 | 11 | 2014 |
PET/MR synchronization by detection of switching gradients B Weissler, P Gebhardt, CW Lerche, GM Soultanidis, J Wehner, ... IEEE Transactions on Nuclear Science 62 (3), 650-657, 2015 | 9 | 2015 |
Reducing interference in a combined assembly for MRI and nuclear imaging B Weissler, P Gebhardt, JAC Wehner, V Schulz US Patent 10,126,391, 2018 | 8 | 2018 |
System for simultaneous PET/MR imaging V Schulz, Y Berker, JAC Wehner US Patent 10,288,702, 2019 | 6 | 2019 |