Do only small uremic toxins, chromophores, contribute to the online dialysis dose monitoring by UV absorbance? J Arund, R Tanner, F Uhlin, I Fridolin Toxins 4 (10), 849-861, 2012 | 27 | 2012 |
Is fluorescence valid to monitor removal of protein bound uremic solutes in dialysis? J Arund, M Luman, F Uhlin, R Tanner, I Fridolin PLoS One 11 (5), e0156541, 2016 | 17 | 2016 |
Removal of urea, β2-microglobulin, and indoxyl sulfate assessed by absorbance and fluorescence in the spent dialysate during hemodialysis K Lauri, J Arund, J Holmar, R Tanner, S Kalle, M Luman, I Fridolin Asaio Journal 66 (6), 698-705, 2020 | 16 | 2020 |
Serum levels and removal by haemodialysis and haemodiafiltration of tryptophan-derived uremic toxins in ESKD patients J Paats, A Adoberg, J Arund, A Dhondt, A Fernström, I Fridolin, G Glorieux, ... International Journal of Molecular Sciences 21 (4), 1522, 2020 | 16 | 2020 |
Estimation of removed uremic toxin indoxyl sulphate during hemodialysis by using optical data of the spent dialysate J Holmar, F Uhlin, R Ferenets, K Lauri, R Tanner, J Arund, M Luman, ... 2013 35th Annual International Conference of the IEEE Engineering in …, 2013 | 15 | 2013 |
Behaviour of uremic toxins and UV absorbance in respect to low and high flux dialyzers. K Lauri, J Arund, R Tanner, J Jerotskaja, M Luman, I Fridolin Estonian Journal of Engineering 16 (1), 2010 | 13 | 2010 |
Quantification of indoxyl sulphate in the spent dialysate using fluorescence spectra J Holmar, J Arund, F Uhlin, R Tanner, I Fridolin 15th Nordic-Baltic Conference on Biomedical Engineering and Medical Physics …, 2011 | 11 | 2011 |
Paracetamol interference in uric Acid levels in uremic patients revealed by monitoring spent dialysate R Tanner, J Arund, I Fridolin, M Luman International Scholarly Research Notices 2013, 2013 | 7 | 2013 |
Beta2-microglobulin measurements in the spent dialysate using fluorescence spectra J Holmar, J Arund, F Uhlin, R Tanner, I Fridolin 5th European Conference of the International Federation for Medical and …, 2012 | 7 | 2012 |
Optical method and biochemical source for the assessment of the middle-molecule uremic toxin β2-microglobulin in spent dialysate J Paats, A Adoberg, J Arund, I Fridolin, K Lauri, L Leis, M Luman, ... Toxins 13 (4), 255, 2021 | 6 | 2021 |
Optical dialysis adequacy monitoring: small uremic toxins and contribution to UV-absorbance studied by HPLC K Lauri, J Arund, J Holmar, R Tanner, M Luman, I Fridolin Progress in Hemodialysis—From Emergent Biotechnology to Clinical Practice …, 2011 | 6 | 2011 |
New optical method for estimation of protein bound uremic toxins elimination J Holmar, J Arund, F Uhlin, R Tanner, I Fridolin World Congress on Medical Physics and Biomedical Engineering May 26-31, 2012 …, 2013 | 4 | 2013 |
4-Pyridoxic Acid in the Spent Dialysate: Contribution to Fluorescence and Optical Monitoring S Kalle, R Tanner, J Arund, R Tomson, M Luman, I Fridolin Plos one 11 (9), e0162346, 2016 | 3 | 2016 |
Treatment with paracetamol can interfere with the intradialytic optical estimation in spent dialysate of uric acid but not of indoxyl sulfate A Adoberg, J Paats, J Arund, A Dhondt, I Fridolin, G Glorieux, J Holmar, ... Toxins 14 (9), 610, 2022 | 2 | 2022 |
Online urea concentration estimation from spent dialysate using optical sensor K Pilt, J Arund, A Adoberg, L Leis, M Luman, I Fridolin XV Mediterranean Conference on Medical and Biological Engineering and …, 2020 | 2 | 2020 |
Can Removal of Middle Molecular Uremic Retention Solutes be Estimated by UV-absorbance Measurements in Spent Dialysate? K Lauri, M Luman, J Holmar, R Tomson, S Kalle, J Arund, F Uhlin, ... World Congress on Medical Physics and Biomedical Engineering, June 7-12 …, 2015 | 2 | 2015 |
Time-averaged concentration estimation of uraemic toxins with different removal kinetics: a novel approach based on intradialytic spent dialysate measurements J Paats, A Adoberg, J Arund, A Dhondt, A Fernström, I Fridolin, G Glorieux, ... Clinical kidney journal 16 (4), 735-744, 2023 | 1 | 2023 |
POS-648 MEDICINES INTAKE INFLUENCES ACCURACY OF THE UREMIC RETENTION MOLECULES’OPTICAL MONITORING IN SPENT DIALYSATE: THE CASE OF UREMIC TOXIN URIC ACID AND PARACETAMOL J Paats, A Adoberg, J Arund, I Fridolin, J Holmar, L Leis, K Pilt, R Tanner, ... Kidney International Reports 7 (2), S277-S278, 2022 | 1 | 2022 |
Intradialytic on-line multicomponent total removed solute monitoring in spent dialysate by a novel miniaturized optical sensor A Adoberg, J Paats, J Arund, L Leis, K Pilt, I Fridolin, M Luman NEPHROLOGY DIALYSIS TRANSPLANTATION 35, 196-196, 2020 | 1 | 2020 |
TO015 INTRADIALYTIC ON-LINE MULTICOMPONENT TOTAL REMOVED SOLUTE MONITORING IN SPENT DIALYSATE BY A NOVEL MINIATURIZED OPTICAL SENSOR A Adoberg, J Paats, J Arund, L Leis, K Pilt, I Fridolin, M Luman Nephrology Dialysis Transplantation 35 (Supplement_3), gfaa141. TO015, 2020 | 1 | 2020 |